Part Number Hot Search : 
HC373 B019N UMX18N P016MB 1N6054E3 AK7714 N411054 XP01114
Product Description
Full Text Search
 

To Download HYD0X1G4CXSE Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 HYD Series
Submersible precision stainless steel pressure transmitters
FEATURES * 0...0.1 to 0...4 bar, (0...1 to 0...40 mH2O) * For corrosive media * 4...20 mA output * Field interchangeable * Intrinsically safe (option)9
MEDIA COMPATIBILITY
Wetted materials: stainless steel 1.4404 (316L)8, Polyethylene, Viton (EPDM) Housing: protection class IP 68 (according to DIN EN 60529) respectively NEMA 6P1
SPECIFICATIONS
Maximum ratings Supply voltage2 (reverse polarity protection) intrinsically safe version (option) Temperature limits Storage Operating Compensated Proof pressure3 0.1 to 0.7 bar 0.7 to 1.5 bar 1.5 to 4.0 bar 13...40 V 17...28 V
ELECTRICAL CONNECTION
+Vs
-20 to +70C -10 to +70C 0 to +65C
+13 to 40 V red sensor V -Vs RL GND
6 bar 10 bar 15 bar
bare
black
June 2008 / 580
1/4
www.sensortechnics.com
HYD Series
Submersible precision stainless steel pressure transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 24 V, tamb = 20C, RL=550 )
C haracteristics
Operating pressure HYD0X1... HYD0X2... HYD0X4... HYD0X7... HYD1X0... HYD1X5... HYD2X0... HYD3X0... HYD4X0...
Min.
0 0 0 0 0 0 0 0 0 3.968 15.968
Typ.
Max.
0.1 0.2 0.4 0.7 1.0 1.5 2 3 4
U nit
bar
Zero pressure offset Full scale span6 Full scale output Thermal effects (0 to 65C) Non-linearity, hysteresis, repeatability5 Long term stability Response time (10 % to 90 %) Power consumption (IL = 20 mA)
4
4.000 16.000 20.0 0.015 0.015
4.032 16.032 mA
Offset Span
%FSS/C 0.2 0.1 %FSS %FSS/year ms mW
50 260
LOAD LIMITATION
intrinsically safe version:
R max =
Vs - 13 V 0.02 A
R max =
Vs - 17 V 0.02 A
June 2008 / 580
2/4
www.sensortechnics.com
HYD Series
Submersible precision stainless steel pressure transmitters
ELECTROMAGNETIC CAPABILITY7
Test conditions
Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) EN61000-4-4: Grade 3 2 kV EN61000-4-2: Grade 4 8 kV, contact discharge EN61000-4-6: Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz)
Criterion
A
B B
A
Specification notes (for all devices):
1. The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting cable. Thus the vent tube of the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation formula. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0C to 65C relative to 20C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 7. Tests are in accordance with EN61000-6-2, April 99. 8. On special request. Hastelloy(c) is available. 9. Certificate: ATEX II 1G (CENELEC EEx ia IIC T4).
June 2008 / 580
3/4
www.sensortechnics.com
HYD Series
Submersible precision stainless steel pressure transmitters
OUTLINE DRAWING
O50
15
150
3m other lengths on request
dimensions in mm
mass: typ. 800 g (without cable)
WIRE CONNECTION
Color red black transparent bare Electrical connection +Vs -Vs vent tube1 case/shield
ORDERING INFORMATION HYD
HYD series submersible pressure ranges10 0X1: 0 to 0.1 bar 0X2: 0 to 0.2 bar 0X4: 0 to 0.4 bar 0X7: 0 to 0.7 bar 1X0: 0 to 1.0 bar 1X5: 0 to 1.5 bar 2X0: 0 to 2 bar 3X0: 0 to 3 bar 4X0: 0 to 4 bar Note 10: Other pressure ranges between 0.1 and 4.0 bar are available on request cable length in m (standard 3 m) cable version output signal 4: 4 - 20 mA pressure mode G: gage pressure
xxx
G
4
C
x
S
E
Option: intrinsically safe9
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. June 2008 / 580 4/4
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of HYD0X1G4CXSE

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X